Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS150SEBA0AAAA — OEM Integrated Ignition Board | Ships Today
ICP

ICP Furnace Control Board Kit for RGS150SEBA0AAAA — OEM Integrated Ignition Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM Control Board Kit (part number 1183618) is the integrated ignition and circuit-control board that manages the heating and blower sequence in your ICP / Tempstar / Heil RGS150SEBA0AAAA gas-electric package unit. The board orchestrates the entire cycle: it processes the thermostat call, runs the inducer and pressure-switch proving, energizes the hot surface igniter, opens the gas valve, monitors flame, and times the blower on/off delays. A failed control board produces erratic or no-heat behavior, ignition lockouts, blower problems, or a completely dead system. Supplied as a complete kit with mounting hardware and instructions, this OEM board restores correct, safe ignition sequencing and full diagnostic LED functionality.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Functions Ignition control, flame sensing, blower & inducer timing
Includes Control board + mounting kit
Fitment OEM exact replacement

Compatibility

Direct OEM replacement kit for the ICP Tempstar Heil RGS150SEBA0AAAA gas-electric package unit. The board's wiring layout, terminal pinout, and ignition sequence are matched to this model family. Confirm your existing board against part 1183618 before ordering.

Installation Guide

  1. Safety First — Disconnect all power to the unit and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the control/blower compartment panel to expose the existing control board.
  3. Document — Photograph every connector, plug, and individual wire on the old board before disconnecting anything.
  4. Remove — Unplug the harnesses, remove the board's mounting screws/standoffs, and lift out the failed board.
  5. Install — Mount the new board with the included hardware and reconnect each harness to the matching terminal per your photos.
  6. Test — Restore power, run a full heat cycle, watch the diagnostic LED, and confirm proper ignition, flame proving, and blower operation.

Signs You Need a Replacement

  • No response on a heat call — dead board, no diagnostic LED
  • Repeated ignition lockouts or error/fault flash codes
  • Blower or inducer runs continuously or fails to start
  • Visible burnt traces, scorched relays, or corroded connectors

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150SEBA0AAAA — OEM Integrated Ignition Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150SEBA0AAAA — OEM Integrated Ignition Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150SEBA0AAAA — OEM Integrated Ignition Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online