Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) brain of the ICP / Tempstar / Heil RGS150SEAA0AAAA gas furnace. It sequences the entire heat cycle — inducer start, pressure-switch proving, hot surface igniter warm-up, gas valve energizing, flame sensing, and blower timing — while monitoring safety limits and reporting diagnostic flash codes. When the board fails, the furnace can present as completely dead, stuck in a single stage, short-cycling, or locking out even when the igniter, valve, and switches are all good. Replacing a degraded board restores reliable, safe ignition and proper blower on/off delays.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board (kit)
Brand ICP / Tempstar / Heil
Line Voltage 120V
Control Voltage 24V
Diagnostics LED flash-code fault reporting
Fit OEM, direct replacement

Compatibility

Built for the ICP / Tempstar / Heil RGS150SEAA0AAAA gas furnace and used across matching RGS-series single-stage furnaces and equivalent Heil/Tempstar/Comfortmaker models of this platform. Verify the board's OEM number against the one in your unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker. Verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the blower-compartment service panel.
  3. Document — Photograph every wire and connector on the existing board before removing anything.
  4. Remove — Unplug all harnesses, release the board mounting screws/standoffs, and lift the old board out.
  5. Install — Mount the new board, then transfer each connection exactly per your photos, confirming low-voltage terminals match.
  6. Test — Restore power, run a full heat cycle, and confirm normal sequencing with no fault flash codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no LED activity on the board.
  • Erratic operation, short-cycling, or blower that won't shut off.
  • Repeated lockouts even after igniter, gas valve, and switches test good.
  • Visible burnt traces, scorched relays, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150SEAA0AAAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150SEAA0AAAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150SEAA0AAAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online