Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) that runs the ICP RGS150LECB0AAAA gas furnace. The board is the brain of the system: it sequences ignition, monitors the flame sensor and limit switches, controls the inducer and blower motors, manages timing and safety lockouts, and communicates with the thermostat. Control boards fail from voltage surges, heat stress, corrosion, and cracked solder joints, producing symptoms ranging from intermittent no-heat to a completely dead furnace. Supplied as a kit with the hardware needed for a clean swap, this board restores full furnace operation and built-in safety logic.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Function Ignition sequencing, blower/inducer control, safety logic
Brand ICP / Tempstar / Heil / Comfortmaker
Fits Model RGS150LECB0AAAA
Application Gas Furnace
Fit OEM Genuine Replacement

Compatibility

Built for the ICP RGS150LECB0AAAA and used across many Tempstar, Heil, and Comfortmaker furnaces sharing this control platform. Verify your model and serial number on the rating plate and compare the board's connector layout to your original before installing.

Installation Guide

  1. Safety First — Shut off gas and disconnect power, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control / blower compartment panel.
  3. Document — Photograph every connector, plug, and wire location on the old board before unplugging anything.
  4. Remove — Unplug the harnesses, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, transfer each connector to the matching terminal per your photos, and set any DIP switches to match the originals.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct ignition, blower, and shutdown sequencing.

Signs You Need a Replacement

  • Furnace is completely dead with no diagnostic LED activity
  • Intermittent operation, random lockouts, or error codes
  • Blower or inducer won't run, or runs at the wrong time
  • Visible burn marks, corrosion, or cracked traces on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150LECB0AAAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150LECB0AAAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150LECB0AAAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.