Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS150LDBA0AAAA — OEM Part 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS150LDBA0AAAA — OEM Part 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM integrated furnace control board kit, part number 1183618, for the ICP / Tempstar / Heil RGS150LDBA0AAAA rooftop gas/electric package unit. The control board is the brain of the heating system — it manages the ignition sequence, sequences the inducer and blower motors, monitors safety limits and flame, and processes the 24V thermostat inputs. When the board fails you may see no heat, no blower, error codes flashing on the diagnostic LED, or intermittent operation. Supplied as a kit with the correct mounting and connector provisions, this OEM board restores full, code-compliant control of the unit.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24 VAC thermostat inputs
Functions Ignition, inducer, blower, safety/limit, diagnostics
Fit OEM exact-fit replacement
Model RGS150LDBA0AAAA

Compatibility

Engineered for the ICP/Tempstar/Heil RGS150LDBA0AAAA and other RGS-series rooftop gas/electric units that specify control board kit 1183618. Match the board part number and connector layout to your original before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the control/electrical service panel to expose the board.
  3. Document — Photograph every plug, terminal, and wire color before disconnecting; note the diagnostic LED location.
  4. Remove — Unplug each harness, release the board standoffs or screws, and remove the failed board.
  5. Install — Mount the new board, transfer every connector to the matching terminal per your photo, and confirm all plugs are fully seated.
  6. Test — Restore power, run a heat and a fan call, and verify the diagnostic LED shows a normal status with proper ignition and blower sequencing.

Signs You Need a Replacement

  • No heat, no blower, or no response to the thermostat
  • Fault/error codes flashing on the board's diagnostic LED
  • Intermittent operation or random shutdowns
  • Visible scorching, corrosion, or burned traces/relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150LDBA0AAAA — OEM Part 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150LDBA0AAAA — OEM Part 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150LDBA0AAAA — OEM Part 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online