Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS150HSCB0AAAA — OEM Part 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS150HSCB0AAAA — OEM Part 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM integrated furnace control board kit (part 1183618) for the ICP / Tempstar / Heil RGS150HSCB0AAAA packaged gas/electric unit. The control board is the brain of the heating system — it sequences the inducer, hot surface igniter, gas valve, and blower, monitors the safety circuit (limits, pressure switch, flame sense), and manages timing and diagnostics. When it fails, the unit may be completely dead, stuck in a single mode, short-cycling, or flashing fault codes with no actual component failure. This factory kit includes the correct board revision and mounting hardware for a clean, reliable replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Voltage 120V Primary / 24V Control
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the ICP RGS150HSCB0AAAA and related RGS-series packaged units that use this control board revision. Confirm the existing board part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photograph every plug, terminal, and harness location on the old board before disconnecting.
  4. Remove — Unplug all connectors, remove the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, transfer each connector exactly per your photo.
  6. Test — Restore power, run a full heat and cool cycle, and confirm correct sequencing with no fault codes.

Signs You Need a Replacement

  • Unit completely unresponsive with power confirmed
  • No igniter, inducer, or blower activation on a call
  • Persistent fault-code flashing with good components
  • Visible burn marks, corrosion, or blown traces/relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150HSCB0AAAA — OEM Part 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150HSCB0AAAA — OEM Part 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150HSCB0AAAA — OEM Part 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online