This OEM control board kit is the brain of the ICP Tempstar Heil RGS150HECB0AAAA 150,000 BTU gas furnace. The integrated furnace control sequences the inducer, igniter, gas valve, and blower, monitors the flame sensor and pressure/limit switches, and runs the safety lockout logic. Boards fail from heat-stressed relays, blown onboard fuses, surge damage, and cracked solder joints — symptoms include a furnace that's completely dead, a blower that never starts (or never stops), no ignition sequence, or a diagnostic LED flashing a fault code. Part 1183618 ships as a complete kit so you can restore reliable operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, blower, and safety sequencing
Application Gas Furnace
Fit OEM Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS150HECB0AAAA furnace and RGS-series sister models that specify control board 1183618. ICP-family brands (Tempstar, Heil, Comfortmaker, Arcoaire) share this control platform — verify the board callout in your unit's parts list before ordering.

Installation Guide

  1. Safety First — Disconnect furnace power at the disconnect or breaker and verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment door to expose the control board.
  3. Document — Photograph every wire and connector position; label harnesses if needed. This is the most important step.
  4. Remove — Unplug all connectors, remove the board mounting screws, and lift out the old board.
  5. Install — Mount the new 1183618 board, then reconnect every harness exactly per your photo. Set any DIP switches / heat-anticipator jumpers to match the original.
  6. Test — Restore power and run a full heat cycle; confirm normal ignition sequence and that the diagnostic LED shows normal operation.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no ignition sequence.
  • Blower runs continuously or never engages on a heat call.
  • Diagnostic LED flashing a hard-fault or internal-control error code.
  • Visible scorching, a blown onboard fuse, or burnt relay on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150HECB0AAAA — OEM Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150HECB0AAAA — OEM Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150HECB0AAAA — OEM Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online