Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS150HEBA0AAAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS150HEBA0AAAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM control board kit (OEM Part 1183618, "KIT CONTROL BOARD") for the ICP / Tempstar / Heil RGS150HEBA0AAAA gas furnace. The integrated furnace control board is the brain of the unit — it sequences ignition, monitors safety switches and flame, and times the inducer and blower motors. When the board fails you may see no response to a call for heat, blower running constantly, or error codes flashing on the diagnostic LED. The kit ships with the board and required mounting/connection hardware.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, blower & safety sequencing
Application Gas furnace

Compatibility

Fits the ICP / Tempstar / Heil RGS150HEBA0AAAA and related RGS-series furnaces specifying control board kit 1183618. Confirm the part number against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power and gas; verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment panel.
  3. Document — Photograph every connector and wire location on the old board.
  4. Remove — Unplug each harness, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board and transfer each connector to the identical position per your photos.
  6. Test — Restore power and gas, run a full heat cycle, and confirm proper ignition, flame proving, and blower timing.

Signs You Need a Replacement

  • No response to a call for heat
  • Blower runs constantly or won't start
  • Diagnostic LED flashing a hard-fault code
  • Visible scorching or burnt traces on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150HEBA0AAAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150HEBA0AAAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150HEBA0AAAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online