Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) that runs the entire heating sequence on your ICP/Tempstar/Heil RGS150HDBA0AAAA. The board manages inducer operation, hot surface igniter timing, gas valve actuation, flame sensing, blower delays, and onboard safety lockouts. When it fails, the furnace can refuse to start, get stuck in a single stage, flash diagnostic fault codes, or run the blower continuously. Because it sits at the center of the ignition sequence, a faulty control board often mimics igniter, flame-sensor, or gas-valve problems — so it's worth confirming with the LED fault code before replacing. This kit ships with the replacement board ready to drop into your existing harness.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition, Blower & Safety Control
Application Gas Furnace

Compatibility

Built for the ICP/Tempstar/Heil RGS150HDBA0AAAA and related ICP-family furnaces using this control kit. Match the board's connector layout and part number against your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment panel.
  3. Document — Photograph every wire and connector on the old board before unplugging anything.
  4. Remove — Unplug each harness, release the mounting standoffs, and lift out the old board.
  5. Install — Seat the new board on the standoffs and reconnect every harness exactly per your photo.
  6. Test — Restore power and run a full heat cycle, confirming proper sequencing and a normal LED status code.

Signs You Need a Replacement

  • No response on a heat call — inducer and igniter never energize
  • Persistent or abnormal LED diagnostic fault codes
  • Blower runs continuously or won't run at all
  • Intermittent operation or random lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS150HDBA0AAAA — OEM Ignition Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS150HDBA0AAAA — OEM Ignition Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS150HDBA0AAAA — OEM Ignition Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online