Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS121STCA0AAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS121STCA0AAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) for the ICP/Tempstar/Heil RGS121STCA0AAA is the brain of the furnace. The integrated furnace control manages the ignition sequence, inducer and blower motor timing, gas valve operation, and all safety interlocks including the limit and pressure switches. When the board fails, the furnace may short cycle, fail to ignite, run the blower continuously, or shut down on safety lockouts. Replacing the board with the correct OEM kit restores reliable, code-compliant operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower & Safety Control
Application Gas Furnace
Fit OEM Direct Replacement

Compatibility

Engineered for the ICP RGS121STCA0AAA and related Tempstar, Heil, and Comfortmaker gas furnaces that use this integrated control board. Verify the part number against your existing board before installing, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace service panel to expose the control board.
  3. Document — Photograph every wire and connector on the board before disconnecting anything.
  4. Remove — Unplug all connectors, unscrew the old board, and lift it from its standoffs.
  5. Install — Mount the new board and reconnect every harness exactly per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower, and safety operation.

Signs You Need a Replacement

  • Furnace short cycles or won't start on a heat call
  • Blower runs continuously or won't run at all
  • Repeated safety lockouts with no other fault found
  • Visible burn marks, corrosion, or blinking fault codes on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121STCA0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121STCA0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121STCA0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online