Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS121LFCB0AAA — OEM Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS121LFCB0AAA — OEM Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) for the ICP / Heil / Tempstar RGS121LFCB0AAA gas furnace. The board is the brain of the furnace: it manages the entire heating sequence — powering the inducer, proving pressure switches, energizing the hot surface igniter, opening the gas valve, monitoring flame via the sensor, and timing the blower on and off. It also runs continuous safety logic and stores diagnostic fault codes on its LED. When the board fails, symptoms range from a completely dead furnace to erratic blower behavior, ignition lockouts, or repeated trips with no apparent component fault. Because it ships as a kit, it includes the hardware needed for a clean OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Fits Model RGS121LFCB0AAA
Function Ignition, blower, and safety sequencing with diagnostics
Fitment OEM exact-fit replacement kit

Compatibility

Designed for the ICP-built RGS121LFCB0AAA furnace and related Heil, Tempstar, and Comfortmaker models using this integrated control. Match the board part number and connector layout to your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel where the control board is mounted.
  3. Document — Photograph every wire harness and connector on the board before unplugging — this is the most important step.
  4. Remove — Unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer connectors one at a time to the matching terminals per your photo, and set any jumpers or DIP switches to match the original.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower timing, and no fault codes on the LED.

Signs You Need a Replacement

  • Furnace completely dead with power confirmed at the board
  • Repeated ignition lockouts with healthy igniter, flame sensor, and gas valve
  • Blower runs continuously or fails to start
  • Diagnostic LED shows a control fault or no light at all

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121LFCB0AAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121LFCB0AAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121LFCB0AAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.