This OEM control board kit (OEM 1183618) is the integrated furnace control (IFC) that runs every sequence on your ICP Tempstar/Heil RGS121HTCB0AAA gas furnace. It manages the ignition sequence, monitors flame and safety limits, energizes the inducer and igniter, opens the gas valve, controls blower timing, and coordinates with the thermostat. When the board fails, the furnace may lock out, fail to ignite, run the blower continuously, or show diagnostic fault codes on the board's LED. This kit ships with the components needed for a complete board replacement.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Line Voltage 120V
Control Voltage 24V
Fitment OEM Replacement Kit

Compatibility

Built for the ICP Tempstar/Heil RGS121HTCB0AAA and matched RGS-series gas furnaces using this integrated control. Match the OEM part number on your existing board before ordering, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power and gas; verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph every harness and terminal connection on the old board.
  4. Remove — Unplug each connector, release the board standoffs/screws, and lift out the old control.
  5. Install — Seat the new board on its standoffs and reconnect every harness exactly per your photo; set any DIP switches to match the original.
  6. Test — Restore power and gas, then run a full heat cycle and confirm no fault codes on the LED.

Signs You Need a Replacement

  • Furnace dead with no LED activity, or a flashing fault code
  • No ignition sequence — inducer, igniter, or gas valve never energizes
  • Blower runs constantly or won't run at all
  • Intermittent operation or repeated safety lockouts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS121HTCB0AAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS121HTCB0AAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS121HTCB0AAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.