Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120SRAA0AAA — OEM Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120SRAA0AAA — OEM Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control (IFC) that manages the operation of the ICP Tempstar Heil RGS120SRAA0AAA gas furnace. The board sequences the ignition cycle, monitors safety interlocks, controls the inducer and blower motors, manages igniter and gas valve timing, and runs onboard diagnostics with fault-code flash signals. As a complete kit it includes the board and necessary mounting hardware for a direct replacement. A failed control board can cause no-heat conditions, erratic blower or inducer behavior, ignition lockouts, or a furnace that won't respond to the thermostat at all. Power surges, moisture, and aged relays are common causes of board failure.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fitment OEM Replacement
Application Gas Furnace Ignition & Blower Control

Compatibility

Built for the ICP Tempstar Heil RGS120SRAA0AAA gas furnace and ICP-family models specifying control board kit 1183618. Always match the OEM part number, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/service panel.
  3. Document — Photograph every wire and connector on the board before disconnecting — this is critical for correct reassembly.
  4. Remove — Unplug each harness, transfer spade connectors, and unfasten the old board from its standoffs.
  5. Install — Mount the new board on the supplied hardware and reconnect every wire and connector exactly per your photos.
  6. Test — Restore power, run a full heat cycle, and verify ignition, blower operation, and a normal status LED.

Signs You Need a Replacement

  • Furnace does not respond to a thermostat heat call
  • Erratic or continuous blower/inducer operation
  • Repeated ignition lockouts with no other fault found
  • Burned spots, corrosion, or a dead/abnormal diagnostic LED on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120SRAA0AAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120SRAA0AAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120SRAA0AAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart