This OEM control board kit (part number 1183618) is the integrated furnace ignition control for the ICP / Tempstar / Heil RGS120SFCB0AAA gas furnace. The board manages the complete heating sequence: it powers the inducer, proves the pressure switch, energizes the hot surface igniter, opens the gas valve, confirms flame via the sensor, and runs the blower on the correct heat and cool timings. It also provides the 24V control signals for thermostat calls and on-board diagnostics. When this board fails, the furnace loses its 'brain' and will not safely sequence a heat cycle. Common failure symptoms include no response to a thermostat call for heat, a furnace that locks out after one or two ignition attempts, a continuously running blower, or a diagnostic LED flashing a hard-fault code. Heat, line-voltage surges, condensation, and rodent damage are the usual culprits.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Application Gas Furnace Ignition Control
Fitment OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP / Tempstar / Heil RGS120SFCB0AAA gas furnace. The same control platform is shared across many ICP-family RGS and matched model variants. Always confirm the part number on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment service panel.
  3. Document — Photograph every wire and connector on the board before disconnecting anything.
  4. Remove — Unplug the wiring harnesses and connectors, then remove the mounting screws and lift the old board out.
  5. Install — Mount the new board, transfer the jumper/timing settings, and reconnect every harness exactly per your photos.
  6. Test — Restore power, call for heat, and confirm a full ignition sequence and correct blower operation; check the diagnostic LED for normal status.

Signs You Need a Replacement

  • No response from the furnace on a call for heat.
  • Repeated ignition lockouts or hard-fault diagnostic codes.
  • Blower runs continuously or fails to start.
  • Visible burn marks, corrosion, or a blown trace/fuse on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120SFCB0AAA | Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120SFCB0AAA | Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120SFCB0AAA | Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online