Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120SFBB0AAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120SFBB0AAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part #1183618) is the integrated furnace control (IFC) brain of the ICP/Tempstar/Heil RGS120SFBB0AAA. It manages the entire heat sequence: it reads the thermostat call, runs the inducer and pressure switch proving, energizes the hot surface igniter, opens the gas valve, monitors flame via the sensor, and times the blower on and off delays. It also stores fault history and flashes diagnostic codes through the onboard LED. When the board fails, the furnace may be completely dead, stuck in lockout, blowing cold air, or short cycling with erratic flash codes. This kit ships with the mounting hardware and instructions needed for a complete swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP
Function Ignition, Blower & Diagnostics
Diagnostics Onboard LED Fault Codes
Fitment OEM Replacement

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RGS120SFBB0AAA gas furnace and related models that use the 1183618 control board kit. Match the board layout and connector positions to your existing control before wiring.

Installation Guide

  1. Safety First — Disconnect power and shut off gas, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control panel to expose the board.
  3. Document — Photograph every plug and wire location before disconnecting — connector positions are critical.
  4. Remove — Unplug the harnesses one at a time and remove the mounting screws or standoffs.
  5. Install — Mount the new board, transfer each connector to the identical position per your photos, and set any DIP switches to match the original.
  6. Test — Restore power and gas, run a full heat cycle, and confirm a steady status LED with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls
  • Continuous lockout or hard fault flash codes
  • Blower or inducer running erratically
  • Burned, scorched, or corroded traces on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120SFBB0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120SFBB0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120SFBB0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online