This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) — the brain of ICP, Tempstar, and Heil gas furnaces. It sequences the entire heat cycle: it reads the thermostat call, runs the inducer and proves the pressure switch, energizes the hot surface igniter, opens the gas valve, monitors flame via the sensor, and times blower on/off delays. It also enforces safety lockouts. When the board fails, you can see no response to a heat call, blower that won't start or won't stop, error codes flashing on the diagnostic LED, or intermittent no-heat faults. This kit is a direct-fit OEM replacement for model RGS120SFBA0AAA.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Function Ignition, Blower & Safety Sequencing
Brand ICP / Tempstar / Heil
Diagnostics On-board Fault LED
Fitment OEM Direct Replacement

Compatibility

Engineered for the ICP / Tempstar / Heil RGS120SFBA0AAA furnace and platform models using this integrated furnace control. Match the part number and connector layout to your existing board before ordering.

Installation Guide

  1. Safety First — Shut off gas and disconnect power. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every connector and wire location before disconnecting.
  4. Remove — Unplug each harness, release the board standoffs, and lift out the old control.
  5. Install — Mount the new board, transfer any jumper/DIP settings, and reconnect each harness to the matching terminal per your photo.
  6. Test — Restore gas and power, run a full heat cycle, and confirm proper ignition, flame sensing, and blower timing with no fault codes.

Signs You Need a Replacement

  • No response to a thermostat heat call.
  • Blower won't start or runs continuously.
  • Fault/error codes flashing on the board LED.
  • Intermittent ignition or random safety lockouts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120SFBA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120SFBA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120SFBA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.