Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120LSCA0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120LSCA0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) for the ICP Tempstar Heil RGS120LSCA0AAA gas furnace is the integrated furnace control that orchestrates the entire heating sequence — igniter warm-up, gas valve timing, inducer and blower operation, flame sensing, and all safety lockouts. The board reads the thermostat, pressure switches, and limit controls, then sequences each component in the correct order. When the board fails, the furnace may short cycle, run the blower continuously, fail to ignite, or go into hard lockout with diagnostic flash codes. This kit includes the replacement board and mounting hardware to restore full, code-correct furnace control.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fitment OEM, model-specific
Application Furnace ignition, blower & safety control

Compatibility

Designed for the ICP / Tempstar / Heil RGS120LSCA0AAA gas furnace and related units using the same integrated control platform. Match the board part number and connector layout to your existing control before installing.

Installation Guide

  1. Safety First — Disconnect power and shut off gas, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every connector and wire position on the old board before disconnecting.
  4. Remove — Unplug each harness, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board with the included hardware and reconnect each harness exactly per your photo.
  6. Test — Restore gas and power, run a full heat cycle, and confirm correct ignition, blower timing, and no fault codes.

Signs You Need a Replacement

  • Furnace short cycles or won't start a heating sequence
  • Blower runs constantly or never engages
  • Diagnostic LED shows a control-fault flash code
  • Visible burnt spots, corrosion, or blown components on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120LSCA0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120LSCA0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120LSCA0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online