Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120LFAB0AAA — OEM Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120LFAB0AAA — OEM Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM furnace control board kit (part 1183618) for the ICP/Tempstar/Heil RGS120LFAB0AAA gas furnace. The integrated control board is the brain of the furnace: it sequences the entire heating cycle — energizing the inducer, proving the pressure switch, powering the hot surface igniter, opening the gas valve, monitoring the flame sensor, and timing the blower on and off. It also enforces the safety circuit, locking out the furnace if any limit, rollout, or flame condition is unsafe. Because the board ties every component together, a failed board can mimic many other faults. Common symptoms include a completely dead furnace with no response to a heat call, an igniter or inducer that never energizes, blower timing that runs constantly or not at all, error codes flashing on the diagnostic LED, and intermittent no-heat that comes and goes with heat or vibration. The kit includes the replacement board ready for field installation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition sequencing, blower timing, safety control
Diagnostics On-board LED fault codes
Fitment OEM direct replacement

Compatibility

Engineered for the ICP RGS120LFAB0AAA gas furnace and related Tempstar, Heil, Comfortmaker, and ICP models that use this integrated control. Match the board part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower panel to reach the board.
  3. Document — Photograph every wire harness and connector, or transfer leads one at a time to avoid mistakes.
  4. Remove — Unplug all harnesses, remove the board mounting screws or standoffs, and lift out the old board.
  5. Install — Mount the new board, reseat each connector in its matching plug per your photos, and confirm all are fully latched.
  6. Test — Restore power, run a full heat cycle, and verify proper ignition, flame sensing, and blower timing with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive to a heat call
  • Igniter, inducer, or blower never energizes in sequence
  • Diagnostic LED flashing a board or sequence fault code
  • Intermittent no-heat that changes with vibration or temperature

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120LFAB0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120LFAB0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120LFAB0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online