This OEM control board kit (OEM 1183618) is the integrated furnace control (IFC) for the ICP/Tempstar/Heil RGS120LEBA0AAA gas furnace — the brain that sequences the entire heating cycle. It manages the inducer motor, hot surface igniter timing, gas valve energizing, flame sensing, and blower on/off delays, while continuously monitoring the safety circuit (pressure switches, limits, and rollout). When the board fails you may see no response at all, an inducer that runs but no ignition, a blower that won't shut off, or a flashing diagnostic LED fault code. Supplied as a complete kit with mounting hardware and instructions, this factory-spec replacement restores correct timing and full safety supervision.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Functions Ignition, Blower, Inducer, Flame Sense, Safety
Fit OEM Replacement

Compatibility

Built as the factory integrated control for the ICP RGS120LEBA0AAA 120,000 BTU gas furnace and equivalent Heil, Tempstar, and Comfortmaker platform models. Match the board part number and connector layout to your existing unit before ordering.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access – Remove the blower/control compartment service panel.
  3. Document – Photograph every wire harness and plug location on the old board before disconnecting.
  4. Remove – Unplug each connector, release the board mounting screws or standoffs, and lift out the failed board.
  5. Install – Mount the new board, transfer each connector to the identical terminal per your photo, and set any DIP switches/jumpers to match.
  6. Test – Restore power, run a full heat cycle, and verify proper ignition, blower timing, and a no-fault LED status.

Signs You Need a Replacement

  • No furnace response on a call for heat
  • Inducer runs but igniter or gas valve never energizes
  • Blower runs constantly or fails to start
  • Flashing diagnostic LED fault or scorched/corroded board traces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120LEBA0AAA – OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120LEBA0AAA – OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120LEBA0AAA – OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online