Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120LDCB0AAA — OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120LDCB0AAA — OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control (IFC) for the ICP/Tempstar/Heil RGS120LDCB0AAA gas furnace. The control board is the brain of the furnace — it sequences the entire heating cycle, managing the inducer motor, hot surface igniter, gas valve, blower timing, and safety interlocks while monitoring the limit and flame-sensing circuits. It also typically carries diagnostic LED fault codes that simplify troubleshooting. Because it controls 120V and 24V circuits simultaneously and is exposed to heat and electrical surges, the control board is a common failure point. Symptoms of a failed board include a furnace that is completely dead, no response to a thermostat call, no inducer or igniter sequence, a blower that runs constantly or not at all, blank or flashing error LEDs, or repeated random lockouts. This kit includes the replacement board for a direct OEM repair.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Line Voltage 120 VAC
Control Voltage 24 VAC
Fitment RGS120LDCB0AAA

Compatibility

Direct OEM replacement control board kit for the ICP/Tempstar/Heil RGS120LDCB0AAA gas furnace. Confirm the part number on your existing board matches 1183618 before ordering, as control boards are model-specific.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control access panel to expose the board.
  3. Document — Photograph every wire and connector position on the old board before disconnecting — this is critical for a control board.
  4. Remove — Unplug each harness and the line-voltage terminals, then unscrew the board from its standoffs.
  5. Install — Mount the new board and reconnect every connector exactly per your photos and the wiring diagram.
  6. Test — Restore power and run a full heat call, confirming inducer, igniter, gas valve, and blower sequence correctly with no fault codes.

Signs You Need a Replacement

  • Furnace is completely dead and unresponsive to thermostat calls
  • No inducer, igniter, or blower sequence on a call for heat
  • Blank, missing, or continuously flashing diagnostic LED codes
  • Repeated random lockouts that other component swaps don't cure

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120LDCB0AAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120LDCB0AAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120LDCB0AAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online