Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120LDAA0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120LDAA0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (ICP part #1183618) is the integrated furnace control (IFC) — the brain of your ICP / Heil / Tempstar RGS120LDAA0AAA gas furnace. It manages the entire heating sequence: it powers the draft inducer, energizes the hot surface igniter, opens the gas valve, monitors the flame sensor, and times the blower on and off. It also coordinates safety lockouts and reads pressure-switch and limit inputs. When the board fails, symptoms range from a completely dead furnace to erratic behavior — short cycling, blower that won't start or won't shut off, no ignition sequence, or fault codes flashing on the diagnostic LED. The kit ships with the board and required mounting hardware for a clean OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar)
Function Ignition, blower, and safety sequencing
Application Gas Furnace

Compatibility

Direct OEM fit for the ICP / Heil / Tempstar RGS120LDAA0AAA gas furnace. Because integrated furnace controls are model-specific in their relay logic and connector layout, always match part #1183618 to your existing board and compare the connector pinout before wiring.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas; verify zero voltage at the board with a multimeter.
  2. Access — Remove the furnace control-compartment door.
  3. Document — Photograph every harness connector and terminal before unplugging — this is the single most important step.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the supplied hardware and reconnect each harness exactly per your photos.
  6. Test — Restore power and gas, call for heat, and verify the full sequence: inducer, igniter, gas valve, flame, and blower.

Signs You Need a Replacement

  • Furnace completely dead with no diagnostic LED activity
  • No ignition sequence despite a thermostat call for heat
  • Blower runs constantly or fails to start
  • Erratic short cycling or fault codes pointing to the control

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120LDAA0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120LDAA0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120LDAA0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online