Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120HTCB0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120HTCB0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control for the ICP/Tempstar/Heil RGS120HTCB0AAA gas furnace. The control board is the brain of the furnace — it sequences the inducer motor, energizes the hot surface igniter, opens the gas valve, proves flame via the flame sensor, and times blower on/off delays while monitoring the limit and pressure safety switches. When the board fails you may see no response to a heat call, a furnace stuck on continuous blower, blown fuses, or erratic flashing diagnostic codes. Replacing the board with the genuine OEM kit restores correct ignition sequencing and all built-in safety interlocks.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V
Functions Ignition, blower, inducer, safety timing
Fitment OEM Direct Replacement Kit

Compatibility

Built for the ICP family model RGS120HTCB0AAA and equivalent ICP, Tempstar, Heil, and Comfortmaker gas furnaces using this integrated control. Confirm the board part number and connector layout against your existing unit.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment panel.
  3. Document — Photograph every connector, plug, and wire location on the old board before disconnecting.
  4. Remove — Unplug all harnesses and unscrew the failed board from its standoffs.
  5. Install — Mount the new board and reconnect each harness to its matching plug per your photo. Set any speed taps or jumpers to match the original.
  6. Test — Restore gas and power and run a full heat cycle, confirming proper ignition sequence and blower timing.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Blower runs continuously or won't start
  • Rapid or abnormal diagnostic LED flash codes
  • Repeated blown low-voltage fuses or no igniter voltage

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120HTCB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120HTCB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120HTCB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online