This OEM control board kit, factory part number 1183618 (KIT CONTROL BOARD), is the electronic brain of the ICP / Tempstar / Heil RGS120HSBB0AAA gas furnace. It manages the entire heat cycle: it powers the draft inducer, monitors the pressure switch and limit safeties, energizes the hot surface igniter, opens the gas valve, proves flame, and controls blower timing. A failed board can cause a no-heat condition, erratic blower operation, blown low-voltage fuses, or a furnace that ignites then short-cycles. Supplied as a complete kit with the hardware needed for a clean swap, this board restores reliable, code-compliant operation and the built-in flash-code diagnostics that make future troubleshooting straightforward.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Fits Model RGS120HSBB0AAA
Control Voltage 24V low voltage
Fitment OEM direct replacement kit

Compatibility

A direct OEM replacement for the ICP / Tempstar / Heil RGS120HSBB0AAA furnace. Because control board revisions vary across production runs, match the existing board's part number or your furnace model and serial before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel to expose the control board.
  3. Document — Photograph every wire and connector on the board before disconnecting anything.
  4. Remove — Label and unplug each harness, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer connections exactly per your photo, and set any required jumpers or DIP switches to match.
  6. Test — Restore power, run a full heat cycle, and confirm correct ignition, flame proving, and blower timing.

Signs You Need a Replacement

  • No response from the furnace on a heat call
  • Repeated blown low-voltage fuses or burnt traces on the old board
  • Erratic blower or inducer operation and random lockouts
  • Diagnostic LED dark or flashing a hard-fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120HSBB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120HSBB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120HSBB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.