Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120HSAB0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120HSAB0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the brain of the ICP Tempstar Heil RGS120HSAB0AAA gas furnace. It manages the ignition sequence, sequences the inducer and blower motors, monitors the limit and pressure switches, runs flame sensing, and handles safety lockouts. When the board fails, the furnace may not respond to a call for heat, may short-cycle, may run the blower continuously, or may lock out with a fault code on the diagnostic LED. Heat stress, voltage surges, and cracked relays or solder joints are common failure causes. The kit includes the matched board and mounting hardware for a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Functions Ignition control, blower/inducer timing, safety lockout, flame sensing
Application Gas furnace
Fit OEM exact replacement

Compatibility

Designed for the ICP Tempstar Heil RGS120HSAB0AAA and related RGS-series furnaces using this integrated control. Confirm the board layout, connector positions, and part number against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and gas, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment panel.
  3. Document — Photograph every wire harness and connector on the existing board before removing anything.
  4. Remove — Unplug each connector, release the board from its standoffs, and lift it out.
  5. Install — Mount the new board on the standoffs and reconnect every harness to the matching connector per your photo.
  6. Test — Restore power and gas, run a full heat cycle, and confirm ignition, blower timing, and the diagnostic LED show normal operation.

Signs You Need a Replacement

  • No response to a call for heat
  • Furnace short-cycles or blower runs nonstop
  • Diagnostic LED shows a control or lockout fault
  • Burned spots, cracked relays, or scorched connectors on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120HSAB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120HSAB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120HSAB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart