Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120HRBB0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120HRBB0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board kit (part number 1183618) is the electronic brain of your ICP RGS120HRBB0AAA gas furnace. It manages the entire heating sequence — sequencing the inducer motor, hot surface igniter, gas valve, and blower while continuously monitoring the pressure switch, limit switches, and flame sensor for safe operation. When the control board fails, the furnace can exhibit a wide range of erratic behavior: no response to a heat call, blower running constantly, short cycling, intermittent operation, or fault-code flashes from the diagnostic LED. Because the board governs every safety interlock, a damaged or corroded board should always be replaced with a correct OEM unit rather than bypassed. This kit ships with the mounting hardware and connectors needed for a straightforward swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, Blower & Safety Sequencing
Application Gas Furnace
Fitment OEM Replacement Kit

Compatibility

Built as a direct OEM fit for the ICP / Tempstar / Heil RGS120HRBB0AAA gas furnace and supplied as a complete kit. As an integrated furnace control it also serves as the correct replacement across compatible ICP-family furnaces specified for this board number.

Installation Guide

  1. Safety First — Disconnect electrical power at the furnace switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment door to reach the control board mounting tray.
  3. Document — Photograph every connector and harness location before unplugging anything; the board has many similar plugs.
  4. Remove — Unplug each harness, release the board from its standoffs or tray, and set the old board aside.
  5. Install — Mount the new board, then reconnect each harness to its matching plug exactly per your photos.
  6. Test — Restore power, call for heat, and verify the full sequence — inducer, igniter, gas valve, and blower — runs without fault codes.

Signs You Need a Replacement

  • Furnace does not respond at all to a thermostat heat call.
  • Blower runs continuously or starts at the wrong time in the cycle.
  • Repeated short cycling or intermittent, unpredictable operation.
  • Diagnostic LED flashes a hard-fault code or stays dark with power applied.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120HRBB0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120HRBB0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120HRBB0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online