Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120HFCB0AAA — 1183618 Integrated Ignition Board | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120HFCB0AAA — 1183618 Integrated Ignition Board | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board kit (part 1183618) is the brain of the ICP / Tempstar / Heil RGS120HFCB0AAA gas furnace. It sequences the ignition system, manages the inducer and blower relays, monitors safety limits and flame sense, and runs the diagnostic LED fault codes. A failed board typically shows up as a dead furnace, blower or inducer that won't start or won't stop, erratic LED codes, or ignition that never initiates even though the igniter and gas valve test good. The kit ships with the mounting and connector hardware needed for a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Voltage 120V primary / 24V control
Fit OEM Replacement
Diagnostics LED fault-code output

Compatibility

Designed for the RGS120HFCB0AAA and shared ICP-platform furnaces marketed under Tempstar, Heil, Comfortmaker, and Arcoaire. Verify the board's OEM number against your existing board, as ICP uses several revisions across the platform.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel.
  3. Document — Photograph every wire and connector position on the existing board before unplugging anything.
  4. Remove — Unplug all harnesses, remove the board mounting screws, and lift the old board out.
  5. Install — Mount the new board, transfer connectors one at a time, and reconnect exactly per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm the LED shows a normal (no-fault) status.

Signs You Need a Replacement

  • Furnace completely unresponsive to thermostat calls
  • Inducer or blower runs continuously or never engages
  • Erratic or no LED diagnostic code
  • No ignition sequence despite a good igniter, valve, and flame sensor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120HFCB0AAA — 1183618 Integrated Ignition Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120HFCB0AAA — 1183618 Integrated Ignition Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120HFCB0AAA — 1183618 Integrated Ignition Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online