Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120HFCA0AAA — OEM Replacement | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120HFCA0AAA — OEM Replacement | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part #1183618) is the integrated furnace control (IFC) — the brain of your ICP/Tempstar/Heil RGS120HFCA0AAA furnace. It manages the entire heating sequence: it receives the thermostat call, runs the inducer and pressure-switch proof, energizes the hot surface igniter, opens the gas valve, monitors flame via the sensor, and controls blower timing and safety lockouts. When the control board fails, the furnace may not respond to the thermostat, may short-cycle, or may flash diagnostic fault codes through its onboard LED. Because the board orchestrates every safety interlock, a failed board is a no-heat condition that cannot be safely bypassed. This kit ships as a complete OEM assembly so the board matches your furnace's ignition and blower logic exactly.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition, blower, and safety sequencing
Diagnostics Onboard LED fault codes
Fits Model RGS120HFCA0AAA

Compatibility

Direct OEM replacement for the ICP Tempstar Heil RGS120HFCA0AAA gas furnace. Control board kit 1183618 is the specified IFC for this platform and related ICP-family furnaces using the same control sequence. Confirm your board's connector layout and part number against 1183618 before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker, shut off gas, and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every wire harness and connector position on the old board before unplugging anything.
  4. Remove — Unplug each harness, release the board standoffs/screws, and lift out the old control board.
  5. Install — Mount the new board on the standoffs and reconnect each harness to its matching connector per your photos.
  6. Test — Restore gas and power, start a heat cycle, and confirm the board runs the full inducer → igniter → gas → flame → blower sequence with no fault codes.

Signs You Need a Replacement

  • Furnace does not respond to thermostat calls for heat
  • Repeated lockouts or LED diagnostic fault codes
  • Blower or inducer runs erratically or won't start
  • Visible burn marks, corrosion, or cracked relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120HFCA0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120HFCA0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120HFCA0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online