Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS120HFAA0AAA — OEM Integrated Ignition Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS120HFAA0AAA — OEM Integrated Ignition Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the direct factory replacement integrated furnace control (IFC) for the ICP / Heil / Tempstar RGS120HFAA0AAA gas furnace. The board is the brain of the furnace: it sequences the inducer, hot surface igniter, gas valve, and blower; monitors the flame sensor and pressure/limit switches; and flashes diagnostic fault codes via its onboard LED. When the board fails — often from a blown onboard fuse, cracked solder, or relay failure — symptoms range from a completely dead furnace to no blower, no ignition, or random short-cycling. Because it ships as a kit, mounting hardware and the necessary harness adapters are included for a clean swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Line Voltage 120V
Control Voltage 24V
Fit OEM Direct Replacement

Compatibility

Designed for the RGS120HFAA0AAA and the shared ICP-family platform (Heil, Tempstar, Comfortmaker, Arcoaire). Verify the board part number printed on your existing control before ordering, as ICP used several revisions.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel.
  3. Document — Photograph every wire and terminal position; label connectors if needed.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board and reconnect each harness exactly per your photo.
  6. Test — Restore power, run a full heat and fan cycle, and confirm no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace completely dead with no diagnostic LED
  • No ignition sequence despite a heat call
  • Blower won't run or runs continuously
  • Repeated unexplained short-cycling or random fault codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS120HFAA0AAA — OEM Integrated Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS120HFAA0AAA — OEM Integrated Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS120HFAA0AAA — OEM Integrated Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.