Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102STCB0AAA — OEM Integrated Control | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102STCB0AAA — OEM Integrated Control | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control that runs the entire heating sequence on the ICP/Heil/Tempstar RGS102STCB0AAA gas furnace. It manages the inducer, hot surface igniter, gas valve, and blower timing while monitoring safety inputs like the pressure switch, flame sensor, and limit. When the board fails, the symptoms range from no response on a call for heat to erratic blower behavior, repeated lockouts, or a furnace that ignites but never sequences correctly. Supplied as a kit, it includes the mounting and connection components needed for a clean replacement that restores proper, safe operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Controls Ignition, Inducer, Gas Valve, Blower, Safeties
Application Gas Furnace
Fit OEM

Compatibility

Designed for the ICP/Heil/Tempstar/Comfortmaker RGS102STCB0AAA gas furnace and related RGS-series models using the same integrated control. Match the board layout and connector configuration to your existing part before ordering.

Installation Guide

  1. Safety First — Shut off gas, disconnect power at the switch and breaker, and verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel.
  3. Document — Photograph every connector and wire location on the board before disconnecting — this is critical for a control board.
  4. Remove — Unplug all harness connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, transfer any jumpers/links, and reconnect each harness to the matching terminal per your photos.
  6. Test — Restore gas and power, call for heat, and verify the full sequence: inducer, igniter, gas valve, flame proof, and blower.

Signs You Need a Replacement

  • No response from the furnace on a call for heat
  • Repeated ignition lockouts with good igniter and sensor
  • Blower runs constantly or not at all
  • Visible burnt traces, scorching, or a blown relay on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102STCB0AAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102STCB0AAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102STCB0AAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online