Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102STAB0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102STAB0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part #1183618) is the integrated furnace control (IFC) brain of the ICP Tempstar Heil RGS102STAB0AAA. It sequences the entire heating cycle — energizing the inducer, proving the pressure switch, firing the hot surface igniter, opening the gas valve, monitoring flame, and timing the blower on and off delays. It also runs safety lockouts and flashes diagnostic fault codes. When the board fails, you can see no response on a call for heat, intermittent operation, blower or inducer that won't start, repeated lockouts, or erratic diagnostic LED codes. Replacing the board restores correct ignition sequencing and safety control. The kit ships with mounting hardware for a direct OEM swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition sequencing, blower timing, safety lockout, diagnostics
Fitment OEM factory replacement kit

Compatibility

Designed for the ICP Tempstar Heil RGS102STAB0AAA and shared ICP-family gas furnaces using this integrated furnace control. Match the board's connector layout and part number to your existing unit before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the blower/control compartment panel.
  3. Document — Photograph every plug and wire location on the old board before unplugging.
  4. Remove — Unplug all connectors, remove the mounting screws or standoffs, and take out the old board.
  5. Install — Mount the new board with the included hardware and reconnect each harness to its matching plug per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition sequencing and a steady diagnostic LED.

Signs You Need a Replacement

  • No response on a call for heat
  • Inducer or blower won't energize
  • Repeated ignition lockouts or short-cycling
  • Erratic or blank diagnostic LED codes

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102STAB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102STAB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102STAB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online