This OEM control board kit (OEM 1183618) is the integrated furnace control (IFC) — the brain of the ICP/Tempstar/Heil RGS102SRCA0AAA gas furnace. It manages the entire heat sequence: it reads the thermostat call, runs the inducer and pressure-switch proving, energizes the hot surface igniter, opens the gas valve, monitors flame via the sensor, and stages the blower on and off. It also handles safety lockouts and flashes diagnostic fault codes via its onboard LED. A failed board produces intermittent no-heat, short cycling, or a completely dead furnace. This is a complete factory kit with the mounting hardware needed for a direct swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24V (line input 120V)
Fits Model RGS102SRCA0AAA
Fitment OEM Direct Replacement

Compatibility

Engineered as the factory ignition control for the ICP RGS102SRCA0AAA furnace and compatible RGS-series single-stage models across the Tempstar, Heil, Comfortmaker, and Carrier International family. Match your existing board's part number to 1183618 and confirm the wiring terminal layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker. Verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the blower compartment service panel to expose the control board.
  3. Document — Photograph every wire and connector position; many terminals look alike.
  4. Remove — Label and disconnect the harnesses, remove the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board, transfer the wiring exactly per your photos, and set any jumpers/dip switches to match the originals.
  6. Test — Restore power, run a full heat cycle, and confirm a steady diagnostic LED with proper igniter, gas valve, and blower sequencing.

Signs You Need a Replacement

  • Furnace is completely dead with no diagnostic LED.
  • Igniter, inducer, or blower fails to energize in sequence.
  • Random short cycling or repeated safety lockouts.
  • Visible burn marks, corrosion, or scorched relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102SRCA0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102SRCA0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102SRCA0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.