This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) brain of the ICP / Tempstar / Heil RGS102SRBA0AAA. It sequences the entire heating cycle — inducer start, pressure switch proving, igniter warm-up, gas valve timing, flame sensing, and blower on/off delays — and provides the safety lockouts that protect the system. Boards fail from voltage surges, cracked solder joints, blown onboard fuses, and burned relays, producing symptoms ranging from no ignition to a blower that never starts or never stops. Supplied as a kit for a direct OEM replacement that restores correct timing and safety logic.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition sequencing, blower & safety control
Control Voltage 24 VAC
Fitment OEM

Compatibility

Built for the RGS102SRBA0AAA and the ICP, Tempstar, Heil, Comfortmaker, and Arcoaire furnaces that specify this control kit. Match the part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment service panel to reach the control board.
  3. Document — Photograph every connector and the wiring diagram label before unplugging anything.
  4. Remove — Unplug the harness connectors, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, set any DIP switches/jumpers to match the original, and reconnect each plug per your photos.
  6. Test — Restore power, run a full heat cycle, and verify inducer, ignition, gas valve, flame sense, and blower all sequence correctly.

Signs You Need a Replacement

  • No response on a heat call — inducer and igniter stay dead
  • Blower runs constantly or never engages
  • Repeated lockouts with diagnostic LED fault codes
  • Visible burn marks, blown fuse, or scorched relays on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102SRBA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102SRBA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102SRBA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.