Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) for the ICP / Tempstar / Heil RGS102SFBA0AAA packaged gas/electric unit. The board is the brain of the heating system: it manages the ignition sequence, sequences the inducer and blower motors, monitors the pressure switch and flame sensor, and runs safety lockouts and self-diagnostics. As a kit, it ships with the mounting hardware and connectors needed for a complete swap. Control boards fail from power surges, heat stress, cracked solder joints, blown onboard fuses, and corroded relays. Symptoms include no response on a heat or fan call, blinking diagnostic LED fault codes, the inducer or blower running continuously or not at all, and intermittent lockouts that clear after a power cycle.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Functions Ignition, blower/inducer timing, safety lockout, diagnostics
Includes Board plus mounting/connector hardware
Fitment OEM Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS102SFBA0AAA packaged unit and related ICP-family models specifying control kit 1183618. Match the board layout and connector plugs to your original before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off the gas supply. Verify zero voltage with a multimeter.
  2. Access — Remove the control/blower compartment service panel.
  3. Document — Photo every wiring harness and plug location on the old board before unplugging anything.
  4. Remove — Unplug each connector, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the supplied hardware and reconnect every harness to the matching plug per your photo.
  6. Test — Restore gas and power, run a full heat and fan cycle, and confirm correct ignition, blower timing, and no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • No response on a heat or fan call
  • Blinking diagnostic LED fault codes
  • Inducer or blower runs constantly or never starts
  • Intermittent lockouts that clear only after cycling power

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102SFBA0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102SFBA0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102SFBA0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.