Overview

This OEM control board kit replaces ICP part number 1183618 for the ICP/Tempstar/Heil RGS102SFAA0AAA gas furnace. The integrated furnace control (IFC) board is the brain of the furnace: it sequences the inducer motor, hot surface igniter, gas valve, and blower, monitors the flame sensor and pressure/limit switches, and stores diagnostic fault codes on its LED. When the board fails, the furnace may be completely dead, ignite erratically, run the blower continuously, or flash a hard-lockout code even when every other component tests good.

Specifications

Spec Value
OEM Part Number 1183618 (Control Board Kit)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Line Voltage 120V
Control Voltage 24V
Fitment OEM Direct Replacement Kit

Compatibility

Designed for the ICP/Tempstar/Heil/Comfortmaker RGS102SFAA0AAA furnace. This kit version supersedes earlier board revisions used on RGS-series furnaces; confirm the OEM number and connector layout on your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker and verify zero voltage with a multimeter.
  2. Access — Remove the furnace blower-compartment service panel.
  3. Document — Photograph every wire harness and terminal on the old board before disconnecting.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, transfer connectors one at a time per your photos, and set any jumpers/dip switches to match.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower timing, and no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive with no LED activity.
  • Blower runs constantly or fails to start.
  • Random lockouts with no faulty igniter, sensor, or switch.
  • Burned, corroded, or cracked traces/relays visible on the board.

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102SFAA0AAA — Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102SFAA0AAA — Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102SFAA0AAA — Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.