Overview

This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) brain of the ICP / Tempstar / Heil RGS102LTCB0AAA gas furnace. The board sequences the entire heat cycle — it manages the inducer, igniter, gas valve, and blower timing, monitors the limit and flame-sense circuits, and stores diagnostic fault codes on its LED. When the board fails from a power surge, a blown onboard fuse, cracked solder joints, or burned relays, the furnace can short-cycle, fail to ignite, leave the blower running constantly, or go completely dead. This factory kit restores correct ignition sequencing and safety monitoring.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Fitment OEM Exact-Fit
Control Voltage 24 VAC
Application Gas Furnace Ignition & Blower Control

Compatibility

Built for the ICP-family RGS102LTCB0AAA and the Tempstar, Heil, and Comfortmaker furnaces that use this integrated control. The kit includes mounting hardware and instructions. Verify OEM number 1183618 against your existing board before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel to expose the control board.
  3. Document — Photograph every wire harness and plug location before disconnecting — terminal labeling is critical.
  4. Remove — Unplug all harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the included hardware and reconnect each harness to its matching terminal per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm proper inducer, igniter, gas, and blower sequencing with no fault codes on the LED.

Signs You Need a Replacement

  • Furnace completely dead with no diagnostic LED
  • Short-cycling or random shutdowns mid-cycle
  • Blower runs constantly or never starts
  • Visible scorch marks, burned relays, or a blown fuse on the board

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LTCB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LTCB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LTCB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.