Overview

This genuine OEM furnace control board kit (Part No. 1183618) is the integrated ignition control for the ICP/Heil/Tempstar RGS102LTAB0AAA gas furnace. The board is the brain of the furnace: it sequences the ignition cycle, energizes the hot surface igniter and gas valve, monitors flame via the sensor, controls the inducer and blower motor timing, and enforces the safety lockouts that shut the system down on a fault. Because it ties every major component together, a failed control board can produce a wide range of symptoms — no heat, no blower, intermittent operation, repeated lockouts, or error codes flashing on the diagnostic LED. This kit ships with the mounting hardware and instructions needed for a complete board swap.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Functions Ignition sequencing, blower/inducer control, flame sense, safety lockout
Application Gas Furnace

Compatibility

Supplied as the factory replacement control board kit for the ICP/Heil/Tempstar RGS102LTAB0AAA. Control boards are model-specific by connector layout and firmware, so match the OEM part number 1183618 to your existing board before ordering. The kit format includes the adapter hardware required when an exact original board is superseded.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter at the board.
  2. Access — Remove the furnace control-compartment service panel.
  3. Document — Photograph every connector and wire location on the old board before unplugging.
  4. Remove — Unplug each harness, release the board standoffs or screws, and lift out the old board.
  5. Install — Mount the new board, then reconnect every harness exactly per your photos, confirming polarized connectors are fully seated.
  6. Test — Restore power, call for heat, and verify a full ignition-to-blower cycle with no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace completely dead with no diagnostic LED activity.
  • Blower or inducer won't run, or runs at the wrong time.
  • Repeated lockouts or erratic, intermittent heating.
  • Visible burn marks, scorched relays, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LTAB0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LTAB0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LTAB0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.