This OEM integrated furnace control board kit (OEM part #1183618) is the brain of your ICP RGS102LSBA0AAA furnace. It sequences the entire heating cycle — energizing the inducer, proving the pressure switch, powering the hot surface igniter, opening the gas valve, monitoring flame, and timing the blower on/off delays. It also coordinates cooling and continuous-fan operation. When a control board fails, the furnace may be completely dead, stuck running the blower, intermittently no-heat, or throwing fault codes on its diagnostic LED. Boards typically fail from power surges, overheating, cracked solder joints, or burnt relays. This kit is the exact OEM replacement and restores full, code-compliant control of every safety and timing function.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Line Voltage 120V
Control Voltage 24V
Fit OEM Replacement

Compatibility

Directly fits the ICP/Heil/Tempstar RGS102LSBA0AAA gas furnace. This board kit services many ICP-family RGS-series furnaces — confirm the board's connector layout and part number against your existing control before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and shut off gas. Verify zero voltage at the board with a multimeter.
  2. Access — Remove the furnace control/blower compartment panel.
  3. Document — Photograph every plug, terminal, and wire color on the old board before removing anything.
  4. Remove — Unplug all connectors and 24V terminals, then unscrew the board from its standoffs.
  5. Install — Mount the new board, transfer each connector to the matching position, and set any dip switches/jumpers to match the original.
  6. Test — Restore power and gas, then run a full heat and cool cycle while watching the diagnostic LED for fault codes.

Signs You Need a Replacement

  • Furnace completely dead with no response to the thermostat
  • Blower runs constantly or won't start at all
  • Intermittent no-heat or random short-cycling
  • Diagnostic LED flashing a hard-fault or control-failure code

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LSBA0AAA — OEM Replacement | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LSBA0AAA — OEM Replacement | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LSBA0AAA — OEM Replacement | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.