This genuine OEM furnace control board kit (part number 1183618) is the electronic brain of the ICP/Tempstar/Heil RGS102LRBA0AAA gas furnace. It manages the entire heating sequence — reading the thermostat call, running the inducer and pressure-switch proof, energizing the hot surface igniter, opening the gas valve, timing the blower on/off delays, and monitoring flame sense and safety limits. The board also stores diagnostic flash codes that pinpoint faults. Control boards fail from power surges, heat stress, corroded relays, and cracked solder joints, producing symptoms ranging from no heat to short cycling to a blower that runs constantly. Supplied as a kit for direct OEM replacement and reliable sequencing.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar
Function Ignition sequencing, blower timing, safety monitoring, diagnostics
Fits Model RGS102LRBA0AAA
Fitment Genuine OEM

Compatibility

Engineered for the ICP-family RGS102LRBA0AAA and equivalent Heil, Tempstar, and Comfortmaker furnaces using this control board kit. Match your old board's part number and connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch/breaker and verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment panel.
  3. Document — Photograph every harness connector and wire location — this is the most important step for a board swap.
  4. Remove — Unplug all connectors, release the board's standoffs/screws, and lift out the old board.
  5. Install — Mount the new board, transfer each connector to the identical position per your photos, and set any required dip switches/jumpers to match.
  6. Test — Restore power, run a full heat cycle, and confirm proper sequencing with no error flash codes.

Signs You Need a Replacement

  • Furnace produces no heat with no igniter or inducer response
  • Short cycling or erratic, inconsistent operation
  • Blower runs continuously or fails to start
  • Diagnostic LED shows a board/internal fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LRBA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LRBA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LRBA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.