Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) — the "brain" of your ICP / Tempstar / Heil RGS102LFCA0AAA furnace. It manages the entire heating sequence: inducer operation, hot surface igniter timing, gas valve actuation, flame sensing, blower speed and timing, and safety lockouts. Supplied as a complete kit with the required mounting and connector hardware for a clean replacement. A failed board commonly causes a completely dead furnace, an inducer or blower that won't start, no ignition sequence, or erratic short-cycling — often after a power surge or component short.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Functions Ignition, blower & inducer timing, flame sensing, safety lockout
Application Gas Furnace

Compatibility

Direct-fit OEM replacement kit for the ICP / Tempstar / Heil RGS102LFCA0AAA gas furnace. Because control boards are revision-sensitive, confirm the kit number and connector layout against your existing board before installing. The kit includes the hardware needed to adapt and mount the board correctly.

Installation Guide

  1. Safety First — Disconnect power to the furnace and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/electrical access panel.
  3. Document — Photograph every plug and wire on the existing board before disconnecting — this is critical for a correct reconnection.
  4. Remove — Unplug all connectors, remove the mounting screws/standoffs, and lift out the old board.
  5. Install — Mount the new board with the supplied kit hardware and reconnect every harness per your photos.
  6. Test — Restore power and run a full heat cycle, confirming ignition, flame proving, and blower operation; check the diagnostic LED for fault codes.

Signs You Need a Replacement

  • Furnace completely dead with no response to a heat call
  • Inducer or blower motor will not energize
  • No ignition sequence or repeated random lockouts
  • Erratic short-cycling or a diagnostic LED showing a control fault

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LFCA0AAA — OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LFCA0AAA — OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LFCA0AAA — OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.