Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102LFBB0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102LFBB0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part number 1183618) is the integrated furnace control (IFC) for the ICP / Tempstar / Heil RGS102LFBB0AAA. The board is the brain of the furnace: it sequences the ignition cycle, runs the inducer and blower motors, monitors safety limits and the flame sensor, and times each stage of heating. When the board fails, the furnace can stop responding to the thermostat, short-cycle, skip ignition, run the blower continuously, or flash diagnostic fault codes. This OEM-spec replacement kit restores correct ignition timing, blower control, and safety monitoring for reliable furnace operation.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Function Ignition sequencing, blower/inducer control, safety monitoring
Fitment OEM — RGS102LFBB0AAA
Application Gas furnace

Compatibility

A direct OEM replacement for the RGS102LFBB0AAA and shared ICP-family furnaces marketed under Tempstar, Heil, and Comfortmaker that use this control board. Match the board part number and connector layout to your existing board before installing.

Installation Guide

  1. Safety First — Disconnect electrical power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment/control service panel to expose the board.
  3. Document — Photograph every harness plug and wire location before disconnecting — this is the most important step.
  4. Remove — Unplug each connector, release the board standoffs/screws, and lift out the old board.
  5. Install — Mount the new board, transfer every connector to the matching header per your photos, and confirm each plug is fully seated.
  6. Test — Restore power, call for heat, and verify the full sequence: inducer, igniter, ignition, and blower with no fault codes.

Signs You Need a Replacement

  • Furnace doesn't respond to the thermostat at all
  • No ignition sequence, or short-cycling between stages
  • Blower runs constantly or won't start
  • Diagnostic LED flashing a board/control fault code

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee. Control board replacement is best performed by a qualified HVAC technician.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LFBB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LFBB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LFBB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online