This OEM control board kit (part 1183618) is the integrated furnace control (IFC) for the ICP/Tempstar/Heil RGS102LFAA0AAA gas furnace. It is the brain of the appliance: it sequences the inducer, hot surface igniter, gas valve, and blower while continuously monitoring the pressure switch, limit, and flame-sense circuits for safe operation. When the board fails, symptoms range from a completely dead furnace to erratic blower behavior, repeated lockouts, or fault-code flashing on the diagnostic LED. The kit includes the board and the mounting hardware needed for a direct OEM replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control (Kit)
Brand ICP / Tempstar / Heil
Control Voltage 24V Control / 120V Line
Fit OEM Replacement
Application Gas Furnace Ignition & Blower Control

Compatibility

Designed for the ICP/Tempstar/Heil RGS102LFAA0AAA furnace. ICP-family furnaces (Comfortmaker, Arcoaire, Heil, Tempstar) often share control platforms — match the printed board number to 1183618 and verify the connector layout before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire and connector on the old board before disconnecting anything.
  4. Remove — Unplug all harnesses, release the board standoffs/screws, and remove the failed control.
  5. Install — Mount the new board, transfer each connector exactly as photographed, and set any speed taps or jumpers to match the original.
  6. Test — Restore power and run a full heat cycle, confirming inducer, igniter, gas, and blower sequence correctly with no fault codes.

Signs You Need a Replacement

  • Furnace is completely unresponsive to a call for heat
  • Blower runs constantly or never starts
  • Repeated ignition lockouts with no other failed component found
  • Diagnostic LED flashes a hardware/control fault or stays dark with power applied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LFAA0AAA — OEM Ignition Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LFAA0AAA — OEM Ignition Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LFAA0AAA — OEM Ignition Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.