Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102LEAA0AAA — OEM | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102LEAA0AAA — OEM | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM integrated furnace control board kit (Part No. 1183618) for the ICP / Tempstar / Heil RGS102LEAA0AAA gas furnace. The control board is the brain of the furnace: it sequences the inducer motor, hot surface igniter, gas valve, and blower while continuously monitoring the pressure switch, limit switches, and flame sensor for safe operation. It also drives the diagnostic LED that flashes fault codes. Control boards fail from heat stress, power surges, corroded relays, and cracked solder joints — symptoms range from a completely dead furnace to intermittent no-heat, blower problems, or repeating lockouts. This kit includes the board and the hardware needed for a direct replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Function Ignition, Blower & Safety Sequencing
Diagnostics LED Fault-Code Output
Fit OEM Direct Replacement

Compatibility

Direct fit for the ICP RGS102LEAA0AAA and other RGS102-series furnaces produced by ICP for Tempstar, Heil, Comfortmaker, and Arcoaire. Match the OEM part number on your existing board before ordering, as ICP used several board revisions across production years.

Installation Guide

  1. Safety First — Turn off the furnace at the service switch and breaker, close the gas valve, and verify zero voltage at the board with a multimeter.
  2. Access — Remove the furnace control-compartment door.
  3. Document — Photograph every harness connector and terminal on the old board before unplugging anything.
  4. Remove — Disconnect all plugs and wires, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board and transfer each connector to the matching position per your photos.
  6. Test — Restore gas and power and run a full heat cycle, watching the diagnostic LED for a normal run signal.

Signs You Need a Replacement

  • Furnace is completely dead with no LED activity
  • Diagnostic LED flashes a hard-fault or internal-control-fault code
  • Blower or inducer runs continuously or fails to start
  • Intermittent no-heat that improves after a power reset

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LEAA0AAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LEAA0AAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LEAA0AAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online