Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102LDBA0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102LDBA0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM integrated furnace control board kit (part 1183618) is the brain of the ICP Tempstar Heil RGS102LDBA0AAA gas furnace. It manages the ignition sequence, blower and inducer timing, safety lockouts, and communication between the thermostat, limit switches, and pressure switches. When the control board fails, the furnace may short-cycle, fail to ignite, run the blower continuously, or stop responding to the thermostat entirely. Boards commonly fail from voltage surges, flame-sensor feedback faults, or burned relays after years of switching the blower and inducer motors. This kit ships with the correct factory firmware and connector layout for a true plug-in replacement, restoring proper sequencing and safety operation.

Specifications

Spec Value
OEM Part Number 1183618 (Kit, Control Board)
Type Integrated Furnace Control Board
Brand ICP / Tempstar / Heil
Control Voltage 24V
Application Gas Furnace Control
Fits Model RGS102LDBA0AAA

Compatibility

Engineered as a direct OEM replacement for the ICP Tempstar Heil RGS102LDBA0AAA furnace. The same control platform is used across many ICP-family RGS-series furnaces (Tempstar, Heil, Comfortmaker, Arcoaire). Verify the board part number and connector configuration against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting anything.
  4. Remove — Unplug all harness connectors, remove the mounting screws, and lift out the failed board.
  5. Install — Mount the new board, then transfer each connector exactly as shown in your photo.
  6. Test — Restore power and run a full heat cycle, confirming correct ignition, blower, and inducer sequencing.

Signs You Need a Replacement

  • Furnace will not respond to thermostat calls for heat.
  • Short-cycling or random lockouts with no other faulty components.
  • Blower or inducer runs constantly or fails to start.
  • Visible burn marks, corrosion, or failed relays on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LDBA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LDBA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LDBA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online