Overview

This is the OEM control board kit (part number 1183618) for the ICP/Tempstar/Heil RGS102LDAA0AAA gas furnace. The integrated furnace control board is the brain of the furnace — it sequences the inducer motor, hot surface igniter, gas valve, and blower, monitors the pressure switch and limit/rollout safeties, reads the flame sensor, and runs the diagnostic LED fault codes. When it fails, the furnace may be completely dead, stuck on the blower, short-cycling, or flashing error codes with no heat. The kit includes the board and the mounting/wiring hardware needed for a clean swap. Replacing the board restores correct ignition timing, blower delays, and safety lockout behavior.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Control Voltage 24 VAC
Functions Ignition sequencing, blower/inducer control, safety monitoring, diagnostic LED codes
Fits Model RGS102LDAA0AAA
Fitment OEM direct replacement

Compatibility

Built for the ICP RGS102LDAA0AAA and the shared ICP furnace platforms sold under the Tempstar, Heil, and Comfortmaker names that use this control board. Confirm the board part number and connector layout against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect electrical power and verify zero voltage at the furnace with a multimeter.
  2. Access — Remove the blower/control compartment service panel.
  3. Document — Photograph every wire harness and connector position on the old board before unplugging.
  4. Remove — Unplug each harness, release the board standoffs/screws, and remove the failed board.
  5. Install — Mount the new board with the supplied hardware and reconnect every harness to the matching terminal per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm correct ignition timing, blower operation, and a normal diagnostic LED.

Signs You Need a Replacement

  • Furnace completely unresponsive with no LED activity
  • No ignition sequence despite a valid thermostat call
  • Blower runs constantly or won't run at all
  • Diagnostic LED flashes a hard control/internal fault code

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102LDAA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102LDAA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102LDAA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online