This genuine OEM control board kit (part 1183618) for the ICP / Heil / Tempstar RGS102HTAA0AAA gas furnace is the integrated furnace control (IFC) that manages the entire heating sequence. It reads the thermostat call, sequences the inducer motor, energizes the hot surface igniter, opens the gas valve, monitors flame through the sensor, and times the blower on and off delays. The board also runs safety logic and flashes diagnostic fault codes via its LED. When the control board fails, the furnace may be completely dead, fail to start the inducer or igniter, short-cycle, or run the blower continuously. Supplied as a kit, it includes the correct board for a direct factory-matched replacement that restores full sequence control and safety monitoring.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Heil / Tempstar / Comfortmaker)
Function Ignition Sequence, Blower Timing, Safety & Diagnostics
Fits Model RGS102HTAA0AAA
Application Gas Furnace
Fit OEM

Compatibility

Designed for the ICP-family RGS102HTAA0AAA gas furnace and related Heil, Tempstar, and Comfortmaker furnaces using the same integrated furnace control. Verify the board part number and connector layout against your original before ordering.

Installation Guide

  1. Safety First — Disconnect furnace power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the control-compartment service panel.
  3. Document — Photograph every wire harness and connector position on the old board.
  4. Remove — Unplug each harness, remove the board mounting screws, and lift out the failed control board.
  5. Install — Mount the new board, transfer connectors to the matching terminals per your photo, and set any DIP switches or jumpers to match the original.
  6. Test — Restore power, run a full heat cycle, and confirm proper sequencing with no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace completely unresponsive to the thermostat
  • No inducer, igniter, or blower activation on a heat call
  • Persistent or erratic diagnostic LED fault codes
  • Short-cycling or blower that runs continuously

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102HTAA0AAA — OEM | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102HTAA0AAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102HTAA0AAA — OEM | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.