Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102HSBA0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102HSBA0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part number 1183618) is the integrated furnace control for the ICP / Tempstar / Heil RGS102HSBA0AAA. The board is the brain of the furnace: it sequences the inducer, igniter, gas valve, and blower, monitors limit and pressure safeties, and runs the diagnostic LED flash codes used during service. A board failure can show up as a dead furnace, a unit stuck in lockout, a blower that never starts or never stops, or erratic short-cycling. Because it ties every major component together, a degraded board often mimics other part failures — replacing it with the correct OEM kit restores proper timing and safety logic in one step. The kit includes the board and mounting hardware for a direct swap.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil)
Control Voltage 24 VAC
Line Voltage 120 VAC
Fitment OEM direct replacement

Compatibility

Designed for the ICP Tempstar Heil RGS102HSBA0AAA furnace and related models that use this integrated control. Confirm the board's connector layout and part number against your existing control before ordering.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the blower compartment door where the control board is mounted.
  3. Document — Photograph every connector and wire location; note any DIP switch or jumper settings on the old board.
  4. Remove — Unplug the harnesses, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board, match any DIP/jumper settings, and reconnect each harness to its keyed plug per your photos.
  6. Test — Restore power and run a full heat and blower cycle; confirm normal flash codes and operation.

Signs You Need a Replacement

  • Furnace completely dead with no diagnostic LED activity
  • Blower runs continuously or never engages
  • Repeated lockouts not traced to igniter, valve, or pressure switch
  • Burnt traces, scorch marks, or a burnt smell on the board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102HSBA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102HSBA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102HSBA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online