Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102HECB0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102HECB0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM control board kit (part 1183618) is the integrated furnace control (IFC) for the ICP Tempstar Heil RGS102HECB0AAA gas furnace. The board is the brain of the furnace: it sequences the inducer, igniter, gas valve, and blower, monitors the pressure switch and flame sensor for safety, and runs self-diagnostics with a fault-code LED. When the board fails, you see intermittent no-heat calls, blower or inducer that won't start or won't stop, scrambled or blank diagnostic codes, or repeated lockouts even after good igniter and sensor parts are installed. The kit includes the board and mounting hardware for a complete replacement.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Control Voltage 24 VAC
Features Ignition sequencing, safety monitoring, diagnostic LED
Fit OEM direct replacement

Compatibility

Built for the ICP RGS102HECB0AAA and shared-platform Tempstar, Heil, and Comfortmaker gas furnaces using this integrated control. Match the connector layout and part number to your original board before installing.

Installation Guide

  1. Safety First — Disconnect furnace power and shut off the gas. Verify zero voltage with a multimeter.
  2. Access — Remove the blower-compartment door to reach the control board.
  3. Document — Photograph every wire harness and connector position before unplugging.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the old board.
  5. Install — Mount the new board with the included hardware and reconnect each harness per your photos.
  6. Test — Restore gas and power, then run a full heat cycle and confirm the diagnostic LED shows normal status.

Signs You Need a Replacement

  • Intermittent or total no-heat with no other fault found
  • Blower or inducer that won't start, or won't shut off
  • Blank, frozen, or erratic diagnostic LED codes
  • Repeated ignition lockouts after replacing igniter and sensor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102HECB0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102HECB0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102HECB0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online