Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS102HDCB0AAA — OEM Module | Ships Today
ICP

ICP Furnace Control Board Kit for RGS102HDCB0AAA — OEM Module | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM control board kit (part 1183618) is the integrated furnace control module for the ICP / Tempstar / Heil RGS102HDCB0AAA gas furnace. The control board is the brain of the furnace: it manages the ignition sequence, monitors safety circuits (limits, pressure switch, flame sensor), times the inducer and blower, and switches the gas valve and igniter on each heat call. When the board fails you may see no response to a thermostat call, blower or inducer that won't start or won't stop, repeated ignition lockouts, or error/diagnostic LED fault codes. Supplied as a complete kit for a straightforward direct replacement, this board restores correct ignition timing, blower control, and built-in safety monitoring.

Specifications

Spec Value
Part Number 1183618 — KIT CONTROL BOARD
Type Integrated furnace control board
Brand ICP / Tempstar / Heil
Function Ignition, blower, inducer & safety control
Supplied As Complete replacement kit
Fitment OEM direct replacement
Application Gas furnace control

Compatibility

Built for the ICP/Tempstar/Heil RGS102HDCB0AAA gas furnace and related RGS-series models specifying this control board kit. Confirm the part number and connector layout against your original board before installing.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control/blower compartment access panel.
  3. Document — Photograph every wire harness and connector position on the old board before disconnecting.
  4. Remove — Unplug all connectors, remove the mounting screws, and lift out the old control board.
  5. Install — Mount the new board, transfer each connector to its matching plug per your photo, and confirm all harnesses are fully seated.
  6. Test — Restore power, start a heat call, and verify the full ignition sequence, blower operation, and absence of fault codes on the diagnostic LED.

Signs You Need a Replacement

  • No response from the furnace on a thermostat heat call
  • Blower or inducer that won't start, or won't shut off
  • Repeated ignition lockouts or erratic operation
  • Diagnostic LED flashing a hard fault / control fault code

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS102HDCB0AAA — OEM Module | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS102HDCB0AAA — OEM Module | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS102HDCB0AAA — OEM Module | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online