This OEM control board kit (part number 1183618) is the integrated furnace control (IFC) — the brain of your ICP Tempstar Heil RGS101SECA0AAA gas furnace. It manages the entire heating sequence: igniter warm-up, gas valve timing, inducer and blower operation, flame sensing, safety lockouts, and the 24V thermostat interface. When the board fails, the furnace may short-cycle, fail to ignite, leave the blower running continuously, or go completely dead. Failures are commonly caused by power surges, cracked solder joints, blown onboard fuses, failed relays, or scorched flame-sense circuitry. Installing a fresh OEM control board restores correct ignition timing and all built-in safety functions.

Specifications

Spec Value
OEM Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP (Tempstar / Heil / Comfortmaker)
Line Voltage 120 VAC
Control Voltage 24 VAC
Application Gas Furnace Ignition & Blower Control
Fit OEM Direct Replacement Kit

Compatibility

Direct OEM fit for the ICP Tempstar Heil RGS101SECA0AAA furnace and the matching control position across ICP-built Tempstar, Heil, Comfortmaker, and Arcoaire furnaces on this platform. The kit form includes the mounting hardware and connector references needed for a clean swap.

Installation Guide

  1. Safety First – Disconnect power at the furnace switch/breaker, then verify zero voltage at the board with a multimeter.
  2. Access – Remove the furnace control/blower compartment panel to expose the board.
  3. Document – Photograph every plug, terminal, and wire color before disconnecting anything.
  4. Remove – Unplug each harness, release the board from its standoffs, and lift it out.
  5. Install – Mount the new board, then reconnect each harness exactly per your photo — connectors are keyed.
  6. Test – Restore power, run a full heat cycle, and verify igniter, gas valve, and blower sequence correctly.

Signs You Need a Replacement

  • Furnace is completely dead with no LED status light
  • Short-cycling or erratic ignition and blower behavior
  • Blower runs nonstop or fails to start
  • Visible burnt traces, scorched relays, or a blown onboard fuse

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS101SECA0AAA – OEM Integrated Control | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS101SECA0AAA – OEM Integrated Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS101SECA0AAA – OEM Integrated Control | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online