This genuine ICP furnace control board kit (part 1183618) is the integrated ignition control and brain of the ICP / Tempstar / Heil RGS101LSCB0AAA gas furnace. The board manages the entire heating sequence — inducer start, igniter warm-up, gas valve timing, flame sensing, blower timing, and safety lockouts — and continuously monitors limit and pressure switches. When a control board fails, the furnace may be completely dead, stall partway through the ignition sequence, short-cycle, or run the blower constantly. The kit includes the OEM board and mounting hardware so you can restore reliable, code-correct operation. Note board orientation and any onboard jumper or DIP settings before swapping.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Tempstar / Heil
Function Ignition control, blower & valve timing, safety monitoring
Fit OEM Genuine Replacement
Application Gas furnace primary control

Compatibility

Designed for the ICP / Tempstar / Heil RGS101LSCB0AAA gas furnace and related ICP-family units using this control kit. Compare the connector layout and board part number against your existing board before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and verify zero voltage with a multimeter.
  2. Access — Remove the furnace control compartment service panel.
  3. Document — Photograph every plug and wire, and record any jumper or DIP switch settings before disconnecting.
  4. Remove — Unplug all connectors and remove the mounting screws holding the old board.
  5. Install — Mount the new board, transfer jumper/DIP settings, and reconnect every harness per your photo.
  6. Test — Restore power, call for heat, and verify a full normal ignition and blower sequence with no fault codes.

Signs You Need a Replacement

  • Furnace completely unresponsive to a heat call
  • Ignition sequence stalls or locks out repeatedly
  • Blower runs constantly or won't start
  • Error/fault LED codes pointing to the control board

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS101LSCB0AAA — OEM Circuit Board | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS101LSCB0AAA — OEM Circuit Board | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS101LSCB0AAA — OEM Circuit Board | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.