Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP Furnace Control Board Kit for RGS101LFCA0AAA — OEM 1183618 | Ships Today
ICP

ICP Furnace Control Board Kit for RGS101LFCA0AAA — OEM 1183618 | Ships Today

SKU: 1183618 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM furnace control board kit (part 1183618) is the integrated ignition control / circuit board for the ICP / Heil / Tempstar RGS101LFCA0AAA gas furnace. The board is the brain of the heating system: it manages the ignition sequence, sequences the inducer and blower motors, monitors flame via the sensor and limit switches, and runs diagnostic LED fault codes. When this board fails the furnace may be completely dead, fail to begin the ignition sequence, short-cycle, or flash an error code. Because it is the central control, a faulty board can mimic many other failures — replacing it restores reliable, code-compliant operation. This is a complete kit, so it includes the components needed to swap the board cleanly.

Specifications

Spec Value
Part Number 1183618
Type Integrated Furnace Control Board Kit
Brand ICP / Heil / Tempstar / Comfortmaker
Application Gas Furnace Ignition & Blower Control
Fit OEM Replacement
Model RGS101LFCA0AAA

Compatibility

Direct-fit replacement for the ICP/Heil/Tempstar/Comfortmaker RGS101LFCA0AAA furnace and RGS-series units that specify OEM control board kit 1183618. Verify the part number printed on your existing board before ordering, as ICP used several board revisions across model years.

Installation Guide

  1. Safety First — Disconnect power at the furnace switch/breaker and verify zero voltage with a multimeter before touching the board.
  2. Access — Remove the furnace blower/control compartment service panel.
  3. Document — Photograph every wire and connector position on the old board before disconnecting; label harnesses if needed.
  4. Remove — Unplug all connectors, remove the board mounting screws/standoffs, and lift the old board out.
  5. Install — Mount the new board on the standoffs and reconnect each harness exactly per your photos.
  6. Test — Restore power, run a full heat cycle, and confirm proper ignition, blower operation, and no fault codes on the diagnostic LED.

Signs You Need a Replacement

  • Furnace is completely unresponsive with power confirmed at the board.
  • Ignition sequence never starts or the inducer/blower won't energize.
  • Persistent or nonsensical diagnostic fault codes.
  • Visible burn marks, scorched traces, or corrosion on the board.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Control Board fit my ICP RGS101LFCA0AAA — OEM 1183618 | Ships Today?
Yes. This is the factory-specified OEM control board for the ICP RGS101LFCA0AAA — OEM 1183618 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the control board on my ICP RGS101LFCA0AAA — OEM 1183618 | Ships Today?
Difficulty: Advanced (1–2 hrs)
Step 1: Turn off breaker. Step 2: PHOTOGRAPH all wire connections before touching anything. Step 3: Label each wire with tape. Step 4: Disconnect all wires, remove old board. Step 5: Mount new board, reconnect all wires matching your photo exactly. Step 6: Restore power and test all modes. Exact part number match is critical.
My HVAC system is completely dead. What could be wrong?
Completely dead HVAC (no LED on board) = failed control board or blown fuse. Check board fuse first (3A or 5A, costs $1–$5). If fuse is good and board has power but no LED, board is dead. Always photograph wiring before replacing.
Is this control board compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP control board?
OEM essential. Control boards are model-specific with precise firmware and connector layouts. Aftermarket boards rarely match all functions and can cause intermittent failures or safety issues. Always match the exact OEM part number.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online